| Parameter | Value |
|---|---|
| Orderable part number | DR1040-100-R |
| Rated inductance | 10 uH ±20% |
| Open circuit inductance (OCL) | 9.6 uH |
| Irms (40 °C rise) | 3.8 A |
| Isat | 4.4 A |
| DCR typical @ 20 °C | 26 mOhm |
| DCR maximum @ 20 °C | 35 mOhm |
| K-factor (Bp-p = K x L x dI) | 5.7 |
| Package | 10.5 x 10.3 mm footprint, 4.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
DCR 26 mOhm is the conduction loss: at the rated current it dissipates about 0.38 W, and that heat has to leave through the terminals and the board.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 35% rolloff at +25 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.
10 uH sits in the middle of the range, and the trade at that point is explicit: 26 mOhm of DCR against 4.4 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
Is Isat a thermal limit?
No. Isat is where the core starts to saturate and the inductance falls by the stated percentage. Temperature is governed by Irms and the board, separately.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.