| Parameter | Value |
|---|---|
| Orderable part number | DR1040-151-R |
| Rated inductance | 150 uH ±20% |
| Open circuit inductance (OCL) | 148 uH |
| Irms (40 °C rise) | 0.85 A |
| Isat | 1.15 A |
| DCR typical @ 20 °C | 356 mOhm |
| DCR maximum @ 20 °C | 430 mOhm |
| K-factor (Bp-p = K x L x dI) | 1.6 |
| Package | 10.5 x 10.3 mm footprint, 4.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
The DC resistance sets the efficiency floor. 356 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 35% rolloff at +25 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.
150 uH sits in the middle of the range, and the trade at that point is explicit: 356 mOhm of DCR against 1.15 A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
How is it mounted?
Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.