Eaton DR1040-220-R - 22 uH 2.5 A Shielded Inductor
Eaton DR1040-220-R - 22 uH 2.5 A Shielded Inductor

Eaton DR1040-220-R - 22 uH 2.5 A Shielded Inductor

Share
Eaton DR1040-220-R: Shielded Drum Core Power Inductor, 22 uH, 2.5 A, DCR 54 mOhm.
    • Product Details
    • Download

    Eaton DR1040-220-R - 22 uH 2.5 A Shielded Inductor

    DR1040-220-R at a glance: shielded drum core inductor, 22 uH, 2.5 A Irms, 2.9 A Isat, DCR 54 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDR1040-220-R
    Rated inductance22 uH ±20%
    Open circuit inductance (OCL)21.1 uH
    Irms (40 °C rise)2.5 A
    Isat2.9 A
    DCR typical @ 20 °C54 mOhm
    DCR maximum @ 20 °C73 mOhm
    K-factor (Bp-p = K x L x dI)4
    Package10.5 x 10.3 mm footprint, 4.0 mm height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.

    Copper loss grows with the square of the current, so 54 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.

    Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 35% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.

    Positioning in the Range

    The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.

    • Typical applications: Server and desktop power supplies, graphics cards, point-of-load modules, portable electronics, printers and peripherals.
    • Same pad as DR1030 and DR1050, so a height change is a drop-in swap on an existing board - the electrical limits change, the layout does not.
    • Data sheet 4147.

    Putting It to Work

    Choose 22 uH when the ripple target is in the middle of the design window: the DCR stays at 54 mOhm and the saturation limit at 2.9 A leaves the transient room it needs.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Is the "-R" suffix important?
    Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.

    How is it mounted?
    Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.

    Why does the DCR have a typical and a maximum?
    Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr1040-shielded-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.