| Parameter | Value |
|---|---|
| Orderable part number | DR1040-220-R |
| Rated inductance | 22 uH ±20% |
| Open circuit inductance (OCL) | 21.1 uH |
| Irms (40 °C rise) | 2.5 A |
| Isat | 2.9 A |
| DCR typical @ 20 °C | 54 mOhm |
| DCR maximum @ 20 °C | 73 mOhm |
| K-factor (Bp-p = K x L x dI) | 4 |
| Package | 10.5 x 10.3 mm footprint, 4.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.
Copper loss grows with the square of the current, so 54 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 35% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.
Choose 22 uH when the ripple target is in the middle of the design window: the DCR stays at 54 mOhm and the saturation limit at 2.9 A leaves the transient room it needs.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
How is it mounted?
Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.