| Parameter | Value |
|---|---|
| Orderable part number | DR1040-330-R |
| Rated inductance | 33 uH ±20% |
| Open circuit inductance (OCL) | 32.6 uH |
| Irms (40 °C rise) | 2.2 A |
| Isat | 2.45 A |
| DCR typical @ 20 °C | 69 mOhm |
| DCR maximum @ 20 °C | 93 mOhm |
| K-factor (Bp-p = K x L x dI) | 3.3 |
| Package | 10.5 x 10.3 mm footprint, 4.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.
DCR 69 mOhm is the conduction loss: at the rated current it dissipates about 0.33 W, and that heat has to leave through the terminals and the board.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 35% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.
At 33 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 69 mOhm DCR - more turns, thinner wire, more resistance.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
How is it mounted?
Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd