Eaton DR1040-331-R 330 uH Shielded Drum Core Inductor
Eaton DR1040-331-R 330 uH Shielded Drum Core Inductor

Eaton DR1040-331-R 330 uH Shielded Drum Core Inductor

Share
Eaton DR1040-331-R: Shielded Drum Core Power Inductor, 330 uH, 0.52 A, DCR 810 mOhm.
    • Product Details
    • Download

    Eaton DR1040-331-R 330 uH Shielded Drum Core Inductor

    DR1040-331-R at a glance: shielded drum core inductor, 330 uH, 0.52 A Irms, 0.7 A Isat, DCR 810 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDR1040-331-R
    Rated inductance330 uH ±20%
    Open circuit inductance (OCL)323 uH
    Irms (40 °C rise)0.52 A
    Isat0.7 A
    DCR typical @ 20 °C810 mOhm
    DCR maximum @ 20 °C1090 mOhm
    K-factor (Bp-p = K x L x dI)1
    Package10.5 x 10.3 mm footprint, 4.0 mm height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.

    At 810 mOhm this is a part where the winding, not the core, decides the temperature rise. The data sheet quotes the typical and the maximum separately for a reason: build your budget on the maximum.

    Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 35% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.

    What This Family Is For

    The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.

    • Typical applications: Server and desktop power supplies, graphics cards, point-of-load modules, portable electronics, printers and peripherals.
    • Same pad as DR1030 and DR1050, so a height change is a drop-in swap on an existing board - the electrical limits change, the layout does not.
    • Data sheet 4147.

    Sizing and Layout Notes

    330 uH is at the high end of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What is the K-factor for?
    It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.

    Is the "-R" suffix important?
    Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.

    Is the "-R" suffix important?
    Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr1040-shielded-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.