Eaton DR1040-680-R 68 uH Shielded Power Inductor, 1.42 A
Eaton DR1040-680-R 68 uH Shielded Power Inductor, 1.42 A

Eaton DR1040-680-R 68 uH Shielded Power Inductor, 1.42 A

Share
Eaton DR1040-680-R: Shielded Drum Core Power Inductor, 68 uH, 1.42 A, DCR 152 mOhm.
    • Product Details
    • Download

    Eaton DR1040-680-R 68 uH Shielded Power Inductor, 1.42 A

    DR1040-680-R at a glance: shielded drum core inductor, 68 uH, 1.42 A Irms, 1.65 A Isat, DCR 152 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDR1040-680-R
    Rated inductance68 uH ±20%
    Open circuit inductance (OCL)65.3 uH
    Irms (40 °C rise)1.42 A
    Isat1.65 A
    DCR typical @ 20 °C152 mOhm
    DCR maximum @ 20 °C183 mOhm
    K-factor (Bp-p = K x L x dI)2.3
    Package10.5 x 10.3 mm footprint, 4.0 mm height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.

    Copper loss grows with the square of the current, so 152 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.

    Isat is the peak current for approximately 35% rolloff at +25 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Series Positioning

    The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.

    • Typical applications: Server and desktop power supplies, graphics cards, point-of-load modules, portable electronics, printers and peripherals.
    • Same pad as DR1030 and DR1050, so a height change is a drop-in swap on an existing board - the electrical limits change, the layout does not.
    • Data sheet 4147.

    Sizing It Into a Design

    Choose 68 uH when the ripple target is in the middle of the design window: the DCR stays at 152 mOhm and the saturation limit at 1.65 A leaves the transient room it needs.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    How is it mounted?
    Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.

    Why does the DCR have a typical and a maximum?
    Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr1040-shielded-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products