| Parameter | Value |
|---|---|
| Orderable part number | DR1040-820-R |
| Rated inductance | 82 uH ±20% |
| Open circuit inductance (OCL) | 87 uH |
| Irms (40 °C rise) | 1.29 A |
| Isat | 1.47 A |
| DCR typical @ 20 °C | 214 mOhm |
| DCR maximum @ 20 °C | 260 mOhm |
| K-factor (Bp-p = K x L x dI) | 2 |
| Package | 10.5 x 10.3 mm footprint, 4.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.
The DC resistance sets the efficiency floor. 214 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 35% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
The DR1040 sits between the 3.0 mm DR1030 and the 5.0 mm DR1050 on the same 10.5 x 10.3 mm pad. It exists so that a design can move up in current without redoing the land pattern - the footprint is identical across all three.
Choose 82 uH when the ripple target is in the middle of the design window: the DCR stays at 214 mOhm and the saturation limit at 1.47 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Is Isat a thermal limit?
No. Isat is where the core starts to saturate and the inductance falls by the stated percentage. Temperature is governed by Irms and the board, separately.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.