| Parameter | Value |
|---|---|
| Orderable part number | DR1050-271-R |
| Rated inductance | 270 uH ±20% |
| Open circuit inductance (OCL) | 264 uH |
| Irms (40 °C rise) | 0.96 A |
| Isat | 0.9 A |
| DCR typical @ 20 °C | 410 mOhm |
| DCR maximum @ 20 °C | 513 mOhm |
| K-factor (Bp-p = K x L x dI) | 1.06 |
| Package | 10.5 x 10.3 mm footprint, 5.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.
Copper loss grows with the square of the current, so 410 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 35% rolloff at +25 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
The DR1050 is the tallest of the 10.5 x 10.3 mm family, and the one that reaches 1000 uH. Where the 3.0 mm part runs out of copper, the 5.0 mm body keeps the winding cool enough to hold its rating.
270 uH sits in the middle of the range, and the trade at that point is explicit: 410 mOhm of DCR against 0.9 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd