| Parameter | Value |
|---|---|
| Orderable part number | DR1050-560-R |
| Rated inductance | 56 uH ±20% |
| Open circuit inductance (OCL) | 56.7 uH |
| Irms (40 °C rise) | 1.96 A |
| Isat | 1.94 A |
| DCR typical @ 20 °C | 98 mOhm |
| DCR maximum @ 20 °C | 123 mOhm |
| K-factor (Bp-p = K x L x dI) | 2.27 |
| Package | 10.5 x 10.3 mm footprint, 5.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.
Copper loss grows with the square of the current, so 98 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
Isat is the peak current for approximately 35% rolloff at +25 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
The DR1050 is the tallest of the 10.5 x 10.3 mm family, and the one that reaches 1000 uH. Where the 3.0 mm part runs out of copper, the 5.0 mm body keeps the winding cool enough to hold its rating.
At 56 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 98 mOhm DCR - more turns, thinner wire, more resistance.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.