| Parameter | Value |
|---|---|
| Orderable part number | DR1050-681-R |
| Rated inductance | 680 uH ±20% |
| Open circuit inductance (OCL) | 708 uH |
| Irms (40 °C rise) | 0.56 A |
| Isat | 0.55 A |
| DCR typical @ 20 °C | 1095 mOhm |
| DCR maximum @ 20 °C | 1369 mOhm |
| K-factor (Bp-p = K x L x dI) | 0.64 |
| Package | 10.5 x 10.3 mm footprint, 5.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.
Copper loss grows with the square of the current, so 1095 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 35% rolloff at +25 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
The DR1050 is the tallest of the 10.5 x 10.3 mm family, and the one that reaches 1000 uH. Where the 3.0 mm part runs out of copper, the 5.0 mm body keeps the winding cool enough to hold its rating.
680 uH is at the high end of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd