| Parameter | Value |
|---|---|
| Orderable part number | DR124-100-R |
| Rated inductance | 10 uH ±20% |
| Open circuit inductance (OCL) | 8.94 uH |
| Irms (40 °C rise) | 4.5 A |
| Isat | 5.8 A |
| DCR typical @ 20 °C | 23.3 mOhm |
| DCR maximum @ 20 °C | 28 mOhm |
| K-factor (Bp-p = K x L x dI) | 3.81 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
The DC resistance sets the efficiency floor. 23.3 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 25% rolloff at +25 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
10 uH sits in the middle of the range, and the trade at that point is explicit: 23.3 mOhm of DCR against 5.8 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.