Eaton DR124-121-R: Low Profile Shielded Drum Core Inductor, 120 uH, 1.3 A, DCR 311.18 mOhm.
    • Product Details
    • Download

    Eaton DR124-121-R 120 uH Shielded Power Inductor, 1.3 A

    DR124-121-R at a glance: shielded drum core inductor, 120 uH, 1.3 A Irms, 1.65 A Isat, DCR 311 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberDR124-121-R
    Rated inductance120 uH ±20%
    Open circuit inductance (OCL)111 uH
    Irms (40 °C rise)1.3 A
    Isat1.65 A
    DCR typical @ 20 °C311 mOhm
    DCR maximum @ 20 °C373 mOhm
    K-factor (Bp-p = K x L x dI)1.08
    Package12.5 x 12.5 x 4.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.

    At 311 mOhm this is a part where the winding, not the core, decides the temperature rise. The data sheet quotes the typical and the maximum separately for a reason: build your budget on the maximum.

    Isat is the peak current for approximately 25% rolloff at +25 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Where This Series Fits

    The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.

    • Typical applications: Notebook power, LCD panels, desktop and servers, DVD players, DC-DC converters, buck/boost/forward/resonant topologies, noise filtering.
    • Frequency range is quoted to 1 MHz - above that the core loss climbs faster than the ripple benefit, and the DCR is no longer the dominant term.
    • Data sheet 4141.

    Sizing It Into a Design

    120 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr124-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.