| Parameter | Value |
|---|---|
| Orderable part number | DR124-150-R |
| Rated inductance | 15 uH ±20% |
| Open circuit inductance (OCL) | 14.2 uH |
| Irms (40 °C rise) | 3.6 A |
| Isat | 4.62 A |
| DCR typical @ 20 °C | 37.3 mOhm |
| DCR maximum @ 20 °C | 44.8 mOhm |
| K-factor (Bp-p = K x L x dI) | 3.02 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.
Copper loss grows with the square of the current, so 37.3 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 25% rolloff at +25 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
At 15 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 37.3 mOhm DCR - more turns, thinner wire, more resistance.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
How is it mounted?
Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.