| Parameter | Value |
|---|---|
| Orderable part number | DR124-181-R |
| Rated inductance | 180 uH ±20% |
| Open circuit inductance (OCL) | 179 uH |
| Irms (40 °C rise) | 1.1 A |
| Isat | 1.3 A |
| DCR typical @ 20 °C | 502 mOhm |
| DCR maximum @ 20 °C | 602 mOhm |
| K-factor (Bp-p = K x L x dI) | 0.87 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
Copper loss grows with the square of the current, so 502 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 25% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
180 uH sits in the middle of the range, and the trade at that point is explicit: 502 mOhm of DCR against 1.3 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.