| Parameter | Value |
|---|---|
| Orderable part number | DR124-221-R |
| Rated inductance | 220 uH ±20% |
| Open circuit inductance (OCL) | 216 uH |
| Irms (40 °C rise) | 1 A |
| Isat | 1.15 A |
| DCR typical @ 20 °C | 558 mOhm |
| DCR maximum @ 20 °C | 670 mOhm |
| K-factor (Bp-p = K x L x dI) | 0.77 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.
At 558 mOhm this is a part where the winding, not the core, decides the temperature rise. The data sheet quotes the typical and the maximum separately for a reason: build your budget on the maximum.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 25% rolloff at +25 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
220 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd