Eaton DR124-330-R - 33 uH 2.6 A Shielded Inductor
Eaton DR124-330-R - 33 uH 2.6 A Shielded Inductor

Eaton DR124-330-R - 33 uH 2.6 A Shielded Inductor

Share
Eaton DR124-330-R: Low Profile Shielded Drum Core Inductor, 33 uH, 2.6 A, DCR 80.83 mOhm.
    • Product Details
    • Download

    Eaton DR124-330-R - 33 uH 2.6 A Shielded Inductor

    DR124-330-R at a glance: shielded drum core inductor, 33 uH, 2.6 A Irms, 3.12 A Isat, DCR 80.8 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDR124-330-R
    Rated inductance33 uH ±20%
    Open circuit inductance (OCL)31.2 uH
    Irms (40 °C rise)2.6 A
    Isat3.12 A
    DCR typical @ 20 °C80.8 mOhm
    DCR maximum @ 20 °C97 mOhm
    K-factor (Bp-p = K x L x dI)2.04
    Package12.5 x 12.5 x 4.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.

    DCR 80.8 mOhm is the conduction loss: at the rated current it dissipates about 0.55 W, and that heat has to leave through the terminals and the board.

    The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 25% rolloff at +25 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.

    Positioning in the Range

    The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.

    • Typical applications: Notebook power, LCD panels, desktop and servers, DVD players, DC-DC converters, buck/boost/forward/resonant topologies, noise filtering.
    • Frequency range is quoted to 1 MHz - above that the core loss climbs faster than the ripple benefit, and the DCR is no longer the dominant term.
    • Data sheet 4141.

    Putting It to Work

    33 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Is Isat a thermal limit?
    No. Isat is where the core starts to saturate and the inductance falls by the stated percentage. Temperature is governed by Irms and the board, separately.

    What is the K-factor for?
    It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr124-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd