| Parameter | Value |
|---|---|
| Orderable part number | DR124-390-R |
| Rated inductance | 39 uH ±20% |
| Open circuit inductance (OCL) | 37.3 uH |
| Irms (40 °C rise) | 2.3 A |
| Isat | 2.85 A |
| DCR typical @ 20 °C | 110 mOhm |
| DCR maximum @ 20 °C | 132 mOhm |
| K-factor (Bp-p = K x L x dI) | 1.86 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.
The DC resistance sets the efficiency floor. 110 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 25% rolloff at +25 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
Choose 39 uH when the ripple target is in the middle of the design window: the DCR stays at 110 mOhm and the saturation limit at 2.85 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd