| Parameter | Value |
|---|---|
| Orderable part number | DR124-681-R |
| Rated inductance | 680 uH ±20% |
| Open circuit inductance (OCL) | 669 uH |
| Irms (40 °C rise) | 0.56 A |
| Isat | 0.65 A |
| DCR typical @ 20 °C | 1846 mOhm |
| DCR maximum @ 20 °C | 2215 mOhm |
| K-factor (Bp-p = K x L x dI) | 0.45 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
DCR 1846 mOhm is the conduction loss: at the rated current it dissipates about 0.58 W, and that heat has to leave through the terminals and the board.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 25% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
At 680 uH this part is at the high end of the family. The winding that produces that inductance is also what sets the 1846 mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
Is Isat a thermal limit?
No. Isat is where the core starts to saturate and the inductance falls by the stated percentage. Temperature is governed by Irms and the board, separately.
How is it mounted?
Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.