| Parameter | Value |
|---|---|
| Orderable part number | DR124-820-R |
| Rated inductance | 82 uH ±20% |
| Open circuit inductance (OCL) | 80.5 uH |
| Irms (40 °C rise) | 1.7 A |
| Isat | 1.94 A |
| DCR typical @ 20 °C | 213 mOhm |
| DCR maximum @ 20 °C | 255 mOhm |
| K-factor (Bp-p = K x L x dI) | 1.27 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.
DCR 213 mOhm is the conduction loss: at the rated current it dissipates about 0.61 W, and that heat has to leave through the terminals and the board.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 25% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
At 82 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 213 mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.