| Parameter | Value |
|---|---|
| Orderable part number | DR124-8R2-R |
| Rated inductance | 8.2 uH ±20% |
| Open circuit inductance (OCL) | 7.45 uH |
| Irms (40 °C rise) | 5.2 A |
| Isat | 6.22 A |
| DCR typical @ 20 °C | 21.7 mOhm |
| DCR maximum @ 20 °C | 26 mOhm |
| K-factor (Bp-p = K x L x dI) | 4.17 |
| Package | 12.5 x 12.5 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
The DC resistance sets the efficiency floor. 21.7 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 25% rolloff at +25 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
The DR124 is the 4.5 mm low-profile member of the 12.5 mm DR family: 0.47 uH to 1000 uH in a body that stays under 5 mm, with current up to 24.4 A. It is the part you reach for when the board is thin but the rail is not small.
8.2 uH sits in the middle of the range, and the trade at that point is explicit: 21.7 mOhm of DCR against 6.22 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd