| Parameter | Value |
|---|---|
| Orderable part number | DR125-124-R |
| Rated inductance | 120000 uH ±20% |
| Open circuit inductance (OCL) | 120630 uH |
| Irms (40 °C rise) | 0.06 A |
| Isat | 0.07 A |
| DCR typical @ 20 °C | 150000 mOhm |
| Volt-microsecond rating | 1521 V-us |
| Package | 12.5 x 12.5 mm footprint, 6.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.
DCR 150000 mOhm is the conduction loss: at the rated current it dissipates about 0.54 W, and that heat has to leave through the terminals and the board.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DR125 is the 6.0 mm member of the 12.5 mm family, with current up to 45 A peak. The larger body spreads the winding over more copper, which is where the current headroom comes from.
Choose 120000 uH when the ripple target is at the high end of the design window: the DCR stays at 150000 mOhm and the saturation limit at 0.07 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd