Eaton DR125-180-R 18 uH Shielded Drum Core Inductor
Eaton DR125-180-R 18 uH Shielded Drum Core Inductor

Eaton DR125-180-R 18 uH Shielded Drum Core Inductor

Share
Eaton DR125-180-R: Shielded Drum Core Power Inductor, 18 uH, 3.81 A, DCR 37.7 mOhm.
    • Product Details
    • Download

    Eaton DR125-180-R 18 uH Shielded Drum Core Inductor

    DR125-180-R at a glance: shielded drum core inductor, 18 uH, 3.81 A Irms, 5.32 A Isat, DCR 37.7 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDR125-180-R
    Rated inductance18 uH ±20%
    Open circuit inductance (OCL)17.7 uH
    Irms (40 °C rise)3.81 A
    Isat5.32 A
    DCR typical @ 20 °C37.7 mOhm
    Volt-microsecond rating19.6 V-us
    Package12.5 x 12.5 mm footprint, 6.0 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.

    At 37.7 mOhm this is a part where the winding, not the core, decides the temperature rise. The data sheet quotes the typical and the maximum separately for a reason: build your budget on the maximum.

    Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 30% rolloff at +20 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.

    Positioning in the Range

    DR125 is the 6.0 mm member of the 12.5 mm family, with current up to 45 A peak. The larger body spreads the winding over more copper, which is where the current headroom comes from.

    • Typical applications: Desktop and servers, DC-DC converters, LCD panels, portable and handheld devices, noise filtering and filter chokes.
    • Peak current and RMS current are different limits on this series; the ripple current adds heating without adding output, so design to Irms for temperature and Isat for headroom.
    • Data sheet 4315.

    Design Notes

    At 18 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 37.7 mOhm DCR - more turns, thinner wire, more resistance.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    Can I run it above the rated current?
    Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.

    Can I run it above the rated current?
    Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.

    What is the K-factor for?
    It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.