| Parameter | Value |
|---|---|
| Orderable part number | DR125-330-R |
| Rated inductance | 33 uH ±20% |
| Open circuit inductance (OCL) | 33.7 uH |
| Irms (40 °C rise) | 3.28 A |
| Isat | 3.84 A |
| DCR typical @ 20 °C | 50.5 mOhm |
| Volt-microsecond rating | 27.2 V-us |
| Package | 12.5 x 12.5 mm footprint, 6.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.
The DC resistance sets the efficiency floor. 50.5 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DR125 is the 6.0 mm member of the 12.5 mm family, with current up to 45 A peak. The larger body spreads the winding over more copper, which is where the current headroom comes from.
At 33 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 50.5 mOhm DCR - more turns, thinner wire, more resistance.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Is Isat a thermal limit?
No. Isat is where the core starts to saturate and the inductance falls by the stated percentage. Temperature is governed by Irms and the board, separately.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.