| Parameter | Value |
|---|---|
| Orderable part number | DR125-681-R |
| Rated inductance | 680 uH ±20% |
| Open circuit inductance (OCL) | 680 uH |
| Irms (40 °C rise) | 0.7 A |
| Isat | 0.85 A |
| DCR typical @ 20 °C | 1100 mOhm |
| Volt-microsecond rating | 122 V-us |
| Package | 12.5 x 12.5 mm footprint, 6.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.
At 1100 mOhm this is a part where the winding, not the core, decides the temperature rise. The data sheet quotes the typical and the maximum separately for a reason: build your budget on the maximum.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DR125 is the 6.0 mm member of the 12.5 mm family, with current up to 45 A peak. The larger body spreads the winding over more copper, which is where the current headroom comes from.
At 680 uH this part is at the high end of the family. The winding that produces that inductance is also what sets the 1100 mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.