| Parameter | Value |
|---|---|
| Orderable part number | DR125-8R2-R |
| Rated inductance | 8.2 uH ±20% |
| Open circuit inductance (OCL) | 8.05 uH |
| Irms (40 °C rise) | 5.54 A |
| Isat | 7.86 A |
| DCR typical @ 20 °C | 17.6 mOhm |
| Volt-microsecond rating | 13.3 V-us |
| Package | 12.5 x 12.5 mm footprint, 6.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.
Copper loss grows with the square of the current, so 17.6 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DR125 is the 6.0 mm member of the 12.5 mm family, with current up to 45 A peak. The larger body spreads the winding over more copper, which is where the current headroom comes from.
Choose 8.2 uH when the ripple target is in the middle of the design window: the DCR stays at 17.6 mOhm and the saturation limit at 7.86 A leaves the transient room it needs.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd