| Parameter | Value |
|---|---|
| Orderable part number | DR127-101-R |
| Rated inductance | 100 uH ±20% |
| Open circuit inductance (OCL) | 99.3 uH |
| Irms (40 °C rise) | 1.96 A |
| Isat | 3.64 A |
| DCR typical @ 20 °C | 163 mOhm |
| Volt-microsecond rating | 53.9 V-us |
| Package | 12.5 x 12.5 mm footprint, 8.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
DCR 163 mOhm is the conduction loss: at the rated current it dissipates about 0.63 W, and that heat has to leave through the terminals and the board.
Isat is the peak current for approximately 30% rolloff at +20 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DR127 is the 8.0 mm tall version of the 12.5 mm DR family and the one that carries the highest current in the range, up to 56 A peak. Same pad as DR125, more height, more copper, more current.
100 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd