| Parameter | Value |
|---|---|
| Orderable part number | DR127-221-R |
| Rated inductance | 220 uH ±20% |
| Open circuit inductance (OCL) | 222 uH |
| Irms (40 °C rise) | 1.29 A |
| Isat | 2.43 A |
| DCR typical @ 20 °C | 376 mOhm |
| Volt-microsecond rating | 80.5 V-us |
| Package | 12.5 x 12.5 mm footprint, 8.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.
DCR 376 mOhm is the conduction loss: at the rated current it dissipates about 0.63 W, and that heat has to leave through the terminals and the board.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DR127 is the 8.0 mm tall version of the 12.5 mm DR family and the one that carries the highest current in the range, up to 56 A peak. Same pad as DR125, more height, more copper, more current.
220 uH sits in the middle of the range, and the trade at that point is explicit: 376 mOhm of DCR against 2.43 A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Is the "-R" suffix important?
Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd