Eaton DR127-3R3-R 3.3 uH Shielded Power Inductor, 10.5 A
Eaton DR127-3R3-R 3.3 uH Shielded Power Inductor, 10.5 A

Eaton DR127-3R3-R 3.3 uH Shielded Power Inductor, 10.5 A

Share
Eaton DR127-3R3-R: Shielded Drum Core Power Inductor, 3.3 uH, 10.5 A, DCR 5.67 mOhm.
    • Product Details
    • Download

    Eaton DR127-3R3-R 3.3 uH Shielded Power Inductor, 10.5 A

    DR127-3R3-R at a glance: shielded drum core inductor, 3.3 uH, 10.5 A Irms, 21.5 A Isat, DCR 5.67 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDR127-3R3-R
    Rated inductance3.3 uH ±20%
    Open circuit inductance (OCL)2.83 uH
    Irms (40 °C rise)10.5 A
    Isat21.5 A
    DCR typical @ 20 °C5.67 mOhm
    Volt-microsecond rating9.1 V-us
    Package12.5 x 12.5 mm footprint, 8.0 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.

    The DC resistance sets the efficiency floor. 5.67 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.

    Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    Series Positioning

    DR127 is the 8.0 mm tall version of the 12.5 mm DR family and the one that carries the highest current in the range, up to 56 A peak. Same pad as DR125, more height, more copper, more current.

    • Typical applications: High current DC-DC converters, servers and desktop power, graphics cards, battery powered systems, filter chokes.
    • At 8 mm the part is tall enough to matter for mechanical clearance and for airflow around neighbouring components - check both before layout.
    • Data sheet 4315.

    Sizing It Into a Design

    Choose 3.3 uH when the ripple target is in the middle of the design window: the DCR stays at 5.67 mOhm and the saturation limit at 21.5 A leaves the transient room it needs.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    What is the K-factor for?
    It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Can I run it above the rated current?
    Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr-high-power-density-high-efficiency-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.