    DR127-8R2-R at a glance: shielded drum core inductor, 8.2 uH, 6.32 A Irms, 12.2 A Isat, DCR 15.7 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberDR127-8R2-R
    Rated inductance8.2 uH ±20%
    Open circuit inductance (OCL)8.86 uH
    Irms (40 °C rise)6.32 A
    Isat12.2 A
    DCR typical @ 20 °C15.7 mOhm
    Volt-microsecond rating16.1 V-us
    Package12.5 x 12.5 mm footprint, 8.0 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.

    At 15.7 mOhm this is a part where the winding, not the core, decides the temperature rise. The data sheet quotes the typical and the maximum separately for a reason: build your budget on the maximum.

    Isat is the peak current for approximately 30% rolloff at +20 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Series Positioning

    DR127 is the 8.0 mm tall version of the 12.5 mm DR family and the one that carries the highest current in the range, up to 56 A peak. Same pad as DR125, more height, more copper, more current.

    • Typical applications: High current DC-DC converters, servers and desktop power, graphics cards, battery powered systems, filter chokes.
    • At 8 mm the part is tall enough to matter for mechanical clearance and for airflow around neighbouring components - check both before layout.
    • Data sheet 4315.

    Design Notes

    8.2 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What is the K-factor for?
    It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    What is the K-factor for?
    It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.