| Parameter | Value |
|---|---|
| Orderable part number | DR73-220-R |
| Rated inductance | 22 uH ±20% |
| Open circuit inductance (OCL) | 22.6 uH |
| Irms (40 °C rise) | 1.62 A |
| Isat | 1.67 A |
| DCR typical @ 20 °C | 107 mOhm |
| Volt-microsecond rating | 17 V-us |
| Package | 7.6 x 7.6 mm footprint, 3.55 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.
DCR 107 mOhm is the conduction loss: at the rated current it dissipates about 0.28 W, and that heat has to leave through the terminals and the board.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 30% rolloff at +20 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DR73 is the smallest of the four DR sizes: a 7.6 x 7.6 mm shielded drum core in a 3.55 mm max height, covering 0.33 uH to 1000 uH across the family. Small package, real current - this is the size that fits a dense point-of-load rail.
22 uH sits in the middle of the range, and the trade at that point is explicit: 107 mOhm of DCR against 1.67 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Is Isat a thermal limit?
No. Isat is where the core starts to saturate and the inductance falls by the stated percentage. Temperature is governed by Irms and the board, separately.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.