| Parameter | Value |
|---|---|
| Orderable part number | DR73-4R7-R |
| Rated inductance | 4.7 uH ±20% |
| Open circuit inductance (OCL) | 4.42 uH |
| Irms (40 °C rise) | 3.09 A |
| Isat | 3.78 A |
| DCR typical @ 20 °C | 29.7 mOhm |
| Volt-microsecond rating | 7.52 V-us |
| Package | 7.6 x 7.6 mm footprint, 3.55 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.
Copper loss grows with the square of the current, so 29.7 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 30% rolloff at +20 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DR73 is the smallest of the four DR sizes: a 7.6 x 7.6 mm shielded drum core in a 3.55 mm max height, covering 0.33 uH to 1000 uH across the family. Small package, real current - this is the size that fits a dense point-of-load rail.
4.7 uH sits in the middle of the range, and the trade at that point is explicit: 29.7 mOhm of DCR against 3.78 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd