Eaton DR74-220-R 22 uH Shielded Drum Core Inductor
Eaton DR74-220-R 22 uH Shielded Drum Core Inductor

Eaton DR74-220-R 22 uH Shielded Drum Core Inductor

Share
Eaton DR74-220-R: Shielded Drum Core Power Inductor, 22 uH, 1.75 A, DCR 92.5 mOhm.
    • Product Details
    • Download

    Eaton DR74-220-R 22 uH Shielded Drum Core Inductor

    DR74-220-R at a glance: shielded drum core inductor, 22 uH, 1.75 A Irms, 2.13 A Isat, DCR 92.5 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDR74-220-R
    Rated inductance22 uH ±20%
    Open circuit inductance (OCL)21.7 uH
    Irms (40 °C rise)1.75 A
    Isat2.13 A
    DCR typical @ 20 °C92.5 mOhm
    Volt-microsecond rating14.7 V-us
    Package7.6 x 7.6 mm footprint, 4.35 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    The Figures Explained

    The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.

    DCR 92.5 mOhm is the conduction loss: at the rated current it dissipates about 0.28 W, and that heat has to leave through the terminals and the board.

    Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 30% rolloff at +20 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.

    Positioning in the Range

    DR74 uses the same 7.6 x 7.6 mm pad as DR73 but stands 4.35 mm tall instead of 3.55 mm. The extra height is what allows the higher current ratings in this size class without changing the land pattern.

    • Typical applications: Desktop and servers, DVD and media players, portable devices, LCD panels, DC-DC converters, buck and boost stages.
    • Because the footprint matches DR73, a current upgrade can be a straight swap - verify the clearance above the part before you commit to the taller body.
    • Data sheet 4315.

    Design Notes

    22 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Is the "-R" suffix important?
    Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.

    Is the "-R" suffix important?
    Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr-high-power-density-high-efficiency-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd