Eaton DR74-221-R - 220 uH 0.56 A Shielded Inductor
Eaton DR74-221-R - 220 uH 0.56 A Shielded Inductor

Eaton DR74-221-R - 220 uH 0.56 A Shielded Inductor

Share
Eaton DR74-221-R: Shielded Drum Core Power Inductor, 220 uH, 0.56 A, DCR 907 mOhm.
    • Product Details
    • Download

    Eaton DR74-221-R - 220 uH 0.56 A Shielded Inductor

    DR74-221-R at a glance: shielded drum core inductor, 220 uH, 0.56 A Irms, 0.66 A Isat, DCR 907 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDR74-221-R
    Rated inductance220 uH ±20%
    Open circuit inductance (OCL)227 uH
    Irms (40 °C rise)0.56 A
    Isat0.66 A
    DCR typical @ 20 °C907 mOhm
    Volt-microsecond rating47.5 V-us
    Package7.6 x 7.6 mm footprint, 4.35 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    The Figures Explained

    Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.

    At 907 mOhm this is a part where the winding, not the core, decides the temperature rise. The data sheet quotes the typical and the maximum separately for a reason: build your budget on the maximum.

    The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.

    Series Positioning

    DR74 uses the same 7.6 x 7.6 mm pad as DR73 but stands 4.35 mm tall instead of 3.55 mm. The extra height is what allows the higher current ratings in this size class without changing the land pattern.

    • Typical applications: Desktop and servers, DVD and media players, portable devices, LCD panels, DC-DC converters, buck and boost stages.
    • Because the footprint matches DR73, a current upgrade can be a straight swap - verify the clearance above the part before you commit to the taller body.
    • Data sheet 4315.

    Design Notes

    At 220 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 907 mOhm DCR - more turns, thinner wire, more resistance.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Why does the DCR have a typical and a maximum?
    Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.

    Can I run it above the rated current?
    Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr-high-power-density-high-efficiency-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products