| Parameter | Value |
|---|---|
| Orderable part number | DR74-820-R |
| Rated inductance | 82 uH ±20% |
| Open circuit inductance (OCL) | 81 uH |
| Irms (40 °C rise) | 0.91 A |
| Isat | 1.11 A |
| DCR typical @ 20 °C | 345 mOhm |
| Volt-microsecond rating | 28.4 V-us |
| Package | 7.6 x 7.6 mm footprint, 4.35 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
This is a surface-mount drum core with a ferrite shield. The winding sits in a pot core so the flux path closes through ferrite rather than through air, which raises the inductance for a given winding and keeps the radiated field small enough to sit next to a sensitive node.
DCR 345 mOhm is the conduction loss: at the rated current it dissipates about 0.29 W, and that heat has to leave through the terminals and the board.
Isat is the peak current for approximately 30% rolloff at +20 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DR74 uses the same 7.6 x 7.6 mm pad as DR73 but stands 4.35 mm tall instead of 3.55 mm. The extra height is what allows the higher current ratings in this size class without changing the land pattern.
Choose 82 uH when the ripple target is in the middle of the design window: the DCR stays at 345 mOhm and the saturation limit at 1.11 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.