Eaton DR74-8R2-R 8.2 uH Shielded Power Inductor, 2.53 A
Eaton DR74-8R2-R 8.2 uH Shielded Power Inductor, 2.53 A

Eaton DR74-8R2-R 8.2 uH Shielded Power Inductor, 2.53 A

Share
Eaton DR74-8R2-R: Shielded Drum Core Power Inductor, 8.2 uH, 2.53 A, DCR 44.1 mOhm.
    • Product Details
    • Download

    Eaton DR74-8R2-R 8.2 uH Shielded Power Inductor, 2.53 A

    DR74-8R2-R at a glance: shielded drum core inductor, 8.2 uH, 2.53 A Irms, 3.4 A Isat, DCR 44.1 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDR74-8R2-R
    Rated inductance8.2 uH ±20%
    Open circuit inductance (OCL)8.57 uH
    Irms (40 °C rise)2.53 A
    Isat3.4 A
    DCR typical @ 20 °C44.1 mOhm
    Volt-microsecond rating9.23 V-us
    Package7.6 x 7.6 mm footprint, 4.35 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A drum core inductor is a coil wound on a bobbin inside a ferrite pot, and the pot is what makes it usable on a switching board: the field stays inside the core instead of spraying across the PCB. That shielding is the difference between a rail that passes emissions and one that needs another filter stage.

    The DC resistance sets the efficiency floor. 44.1 mOhm at 20 °C rises by roughly a third at 100 °C in copper, so the loss at the hot corner is the number to budget with.

    The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.

    What This Family Is For

    DR74 uses the same 7.6 x 7.6 mm pad as DR73 but stands 4.35 mm tall instead of 3.55 mm. The extra height is what allows the higher current ratings in this size class without changing the land pattern.

    • Typical applications: Desktop and servers, DVD and media players, portable devices, LCD panels, DC-DC converters, buck and boost stages.
    • Because the footprint matches DR73, a current upgrade can be a straight swap - verify the clearance above the part before you commit to the taller body.
    • Data sheet 4315.

    Putting It to Work

    At 8.2 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 44.1 mOhm DCR - more turns, thinner wire, more resistance.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Why does the DCR have a typical and a maximum?
    Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Is the "-R" suffix important?
    Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr-high-power-density-high-efficiency-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message