| Parameter | Value |
|---|---|
| Orderable part number | DRA124-220-R |
| Rated inductance | 22 uH ±20% |
| Open circuit inductance (OCL) | 23 uH |
| Irms (40 °C rise) | 2.44 A |
| Isat1 (30% rolloff @ +25 °C) | 4.16 A |
| Isat2 (40% rolloff @ +125 °C) | 3.33 A |
| DCR typical @ 20 °C | 71 mOhm |
| DCR maximum @ 20 °C | 86 mOhm |
| K-factor (Bp-p = K x L x dI) | 26.6 |
| Package | 12.5 x 12.5 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.
Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRA124 is the low-profile 12.5 mm AEC-Q200 part. It brings the current capability of the large size into a body that still fits under a module cover.
Choose 22 uH when the ripple target is in the middle of the design window: the DCR stays at 71 mOhm and the saturation limit at 4.16 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Why are there two Isat values?
The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.