Eaton DRA124-2R2-R: AEC-Q200 Automotive Shielded Drum Core Inductor, 2.2 uH, 7.64 A, DCR 7 mOhm.
    • Product Details
    • Download

    Eaton DRA124-2R2-R - 2.2 uH AEC-Q200 Power Inductor

    DRA124-2R2-R at a glance: shielded drum core inductor, 2.2 uH, 7.64 A Irms, 14 A Isat, DCR 7 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDRA124-2R2-R
    Rated inductance2.2 uH ±20%
    Open circuit inductance (OCL)2.04 uH
    Irms (40 °C rise)7.64 A
    Isat1 (30% rolloff @ +25 °C)14 A
    Isat2 (40% rolloff @ +125 °C)11.2 A
    DCR typical @ 20 °C7 mOhm
    DCR maximum @ 20 °C9 mOhm
    K-factor (Bp-p = K x L x dI)89.5
    Package12.5 x 12.5 mm footprint
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    This is the automotive grade version of the drum core family: AEC-Q200 qualified, shielded, and rated to 165 °C including self-temperature rise. The electrical behaviour is familiar; the qualification and the mechanical build are not.

    Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Positioning in the Range

    DRA124 is the low-profile 12.5 mm AEC-Q200 part. It brings the current capability of the large size into a body that still fits under a module cover.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, infotainment, DC-DC modules.
    • AEC-Q200 covers the qualification, not the application: the vibration and thermal profile of the actual mounting point still decides the service life.
    • Data sheet 4319.

    Sizing and Layout Notes

    2.2 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

    Mechanical Dimensions

    eaton-dra-automotive-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.