| Parameter | Value |
|---|---|
| Orderable part number | DRA124-6R8-R |
| Rated inductance | 6.8 uH ±20% |
| Open circuit inductance (OCL) | 7.28 uH |
| Irms (40 °C rise) | 4.46 A |
| Isat1 (30% rolloff @ +25 °C) | 7.33 A |
| Isat2 (40% rolloff @ +125 °C) | 5.87 A |
| DCR typical @ 20 °C | 21 mOhm |
| DCR maximum @ 20 °C | 26 mOhm |
| K-factor (Bp-p = K x L x dI) | 46.9 |
| Package | 12.5 x 12.5 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.
The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRA124 is the low-profile 12.5 mm AEC-Q200 part. It brings the current capability of the large size into a body that still fits under a module cover.
Choose 6.8 uH when the ripple target is in the middle of the design window: the DCR stays at 21 mOhm and the saturation limit at 7.33 A leaves the transient room it needs.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Is the part shielded?
Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
What does AEC-Q200 cover?
The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd