| Parameter | Value |
|---|---|
| Orderable part number | DRA125-150-R |
| Rated inductance | 15 uH ±20% |
| Open circuit inductance (OCL) | 14.7 uH |
| Irms (40 °C rise) | 4.45 A |
| Isat1 (30% rolloff @ +25 °C) | 5.72 A |
| Isat2 (40% rolloff @ +125 °C) | 4.58 A |
| DCR typical @ 20 °C | 27 mOhm |
| DCR maximum @ 20 °C | 33 mOhm |
| K-factor (Bp-p = K x L x dI) | 30.5 |
| Package | 12.5 x 12.5 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.
Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DRA125 is the 12.5 mm AEC-Q200 part at mid height - more current than DRA124, same footprint, so an upgrade does not force a board respin.
Choose 15 uH when the ripple target is in the middle of the design window: the DCR stays at 27 mOhm and the saturation limit at 5.72 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Is the part shielded?
Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.
Why are there two Isat values?
The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.
Is the part shielded?
Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd