| Parameter | Value |
|---|---|
| Orderable part number | DRA125-R47-R |
| Rated inductance | 0.47 uH ±20% |
| Open circuit inductance (OCL) | 0.45 uH |
| Irms (40 °C rise) | 14.7 A |
| Isat1 (30% rolloff @ +25 °C) | 33.2 A |
| Isat2 (40% rolloff @ +125 °C) | 26.6 A |
| DCR typical @ 20 °C | 2.5 mOhm |
| DCR maximum @ 20 °C | 3 mOhm |
| K-factor (Bp-p = K x L x dI) | 177 |
| Package | 12.5 x 12.5 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.
Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRA125 is the 12.5 mm AEC-Q200 part at mid height - more current than DRA124, same footprint, so an upgrade does not force a board respin.
Choose 0.47 uH when the ripple target is at the low end of the design window: the DCR stays at 2.5 mOhm and the saturation limit at 33.2 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
What is the operating temperature?
-40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd