| Parameter | Value |
|---|---|
| Orderable part number | DRA127-102-R |
| Rated inductance | 1000 uH ±20% |
| Open circuit inductance (OCL) | 999 uH |
| Irms (40 °C rise) | 0.6 A |
| Isat1 (30% rolloff @ +25 °C) | 1.1 A |
| Isat2 (40% rolloff @ +125 °C) | 0.88 A |
| DCR typical @ 20 °C | 1750 mOhm |
| DCR maximum @ 20 °C | 2100 mOhm |
| K-factor (Bp-p = K x L x dI) | 2.4 |
| Package | 12.5 x 12.5 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.
Thermal margin in a module is not the same as thermal margin on a bench. The ratings assume a mounting condition; the enclosure, the potting and the neighbouring components change it.
Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRA127 is the tallest and highest-current AEC-Q200 drum core in the DRA range, up to 56 A. Built for the under-hood and high-vibration end of automotive.
1000 uH is at the high end of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Why are there two Isat values?
The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.
Is the part shielded?
Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.
What does AEC-Q200 cover?
The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd