| Parameter | Value |
|---|---|
| Orderable part number | DRA127-3R3-R |
| Rated inductance | 3.3 uH ±20% |
| Open circuit inductance (OCL) | 3.51 uH |
| Irms (40 °C rise) | 8.54 A |
| Isat1 (30% rolloff @ +25 °C) | 18.7 A |
| Isat2 (40% rolloff @ +125 °C) | 14.9 A |
| DCR typical @ 20 °C | 8.6 mOhm |
| DCR maximum @ 20 °C | 10.4 mOhm |
| K-factor (Bp-p = K x L x dI) | 40 |
| Package | 12.5 x 12.5 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.
Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRA127 is the tallest and highest-current AEC-Q200 drum core in the DRA range, up to 56 A. Built for the under-hood and high-vibration end of automotive.
3.3 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What is the operating temperature?
-40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
What is the operating temperature?
-40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.