| Parameter | Value |
|---|---|
| Orderable part number | DRA127-681-R |
| Rated inductance | 680 uH ±20% |
| Open circuit inductance (OCL) | 677 uH |
| Irms (40 °C rise) | 0.74 A |
| Isat1 (30% rolloff @ +25 °C) | 1.33 A |
| Isat2 (40% rolloff @ +125 °C) | 1.06 A |
| DCR typical @ 20 °C | 1150 mOhm |
| DCR maximum @ 20 °C | 1390 mOhm |
| K-factor (Bp-p = K x L x dI) | 2.8 |
| Package | 12.5 x 12.5 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
This is the automotive grade version of the drum core family: AEC-Q200 qualified, shielded, and rated to 165 °C including self-temperature rise. The electrical behaviour is familiar; the qualification and the mechanical build are not.
Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.
Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRA127 is the tallest and highest-current AEC-Q200 drum core in the DRA range, up to 56 A. Built for the under-hood and high-vibration end of automotive.
680 uH sits at the high end of the range, and the trade at that point is explicit: 1150 mOhm of DCR against 1.33 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
Is the part shielded?
Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd