| Parameter | Value |
|---|---|
| Orderable part number | DRA73-101-R |
| Rated inductance | 100 uH ±20% |
| Open circuit inductance (OCL) | 102 uH |
| Irms (40 °C rise) | 0.68 A |
| Isat1 (30% rolloff @ +25 °C) | 0.76 A |
| Isat2 (40% rolloff @ +125 °C) | 0.61 A |
| DCR typical @ 20 °C | 609 mOhm |
| DCR maximum @ 20 °C | 731 mOhm |
| K-factor (Bp-p = K x L x dI) | 32.8 |
| Package | 7.6 x 7.6 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
At 165 °C the copper resistivity is about 60% higher than at 20 °C, so the DCR in the table is optimistic at the hot corner - budget the loss accordingly.
Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRA73 is the smallest AEC-Q200 part in the DRA range: a 7.6 x 7.6 mm shielded drum core qualified to 165 °C ambient plus self-heating, built for shock and vibration rather than for a benign bench supply.
At 100 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 609 mOhm DCR - more turns, thinner wire, more resistance.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What is the operating temperature?
-40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
Why are there two Isat values?
The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.