| Parameter | Value |
|---|---|
| Orderable part number | DRA73-1R5-R |
| Rated inductance | 1.5 uH ±20% |
| Open circuit inductance (OCL) | 1.36 uH |
| Irms (40 °C rise) | 5.39 A |
| Isat1 (30% rolloff @ +25 °C) | 6.73 A |
| Isat2 (40% rolloff @ +125 °C) | 5.38 A |
| DCR typical @ 20 °C | 9.7 mOhm |
| DCR maximum @ 20 °C | 11.7 mOhm |
| K-factor (Bp-p = K x L x dI) | 289 |
| Package | 7.6 x 7.6 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
This is the automotive grade version of the drum core family: AEC-Q200 qualified, shielded, and rated to 165 °C including self-temperature rise. The electrical behaviour is familiar; the qualification and the mechanical build are not.
Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DRA73 is the smallest AEC-Q200 part in the DRA range: a 7.6 x 7.6 mm shielded drum core qualified to 165 °C ambient plus self-heating, built for shock and vibration rather than for a benign bench supply.
Choose 1.5 uH when the ripple target is in the middle of the design window: the DCR stays at 9.7 mOhm and the saturation limit at 6.73 A leaves the transient room it needs.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
What is the operating temperature?
-40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.