Eaton DRA73-6R8-R AEC-Q200 Shielded Inductor, 6.8 uH
Eaton DRA73-6R8-R AEC-Q200 Shielded Inductor, 6.8 uH

Eaton DRA73-6R8-R AEC-Q200 Shielded Inductor, 6.8 uH

Share
Eaton DRA73-6R8-R: AEC-Q200 Automotive Shielded Drum Core Inductor, 6.8 uH, 2.62 A, DCR 41 mOhm.
    • Product Details
    • Download

    Eaton DRA73-6R8-R AEC-Q200 Shielded Inductor, 6.8 uH

    DRA73-6R8-R at a glance: shielded drum core inductor, 6.8 uH, 2.62 A Irms, 2.96 A Isat, DCR 41 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDRA73-6R8-R
    Rated inductance6.8 uH ±20%
    Open circuit inductance (OCL)6.63 uH
    Irms (40 °C rise)2.62 A
    Isat1 (30% rolloff @ +25 °C)2.96 A
    Isat2 (40% rolloff @ +125 °C)2.37 A
    DCR typical @ 20 °C41 mOhm
    DCR maximum @ 20 °C49 mOhm
    K-factor (Bp-p = K x L x dI)127
    Package7.6 x 7.6 mm footprint
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    AEC-Q200 is the entry ticket, not the destination. This part is qualified to the automotive standard and rated to 165 °C ambient plus self-heating, in a shielded drum core built to survive shock and vibration rather than a laboratory bench.

    The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.

    The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.

    Where This Series Fits

    DRA73 is the smallest AEC-Q200 part in the DRA range: a 7.6 x 7.6 mm shielded drum core qualified to 165 °C ambient plus self-heating, built for shock and vibration rather than for a benign bench supply.

    • Typical applications: Body electronics, LED lighting, HVAC controllers, door and seat modules, ADAS and infotainment supplies.
    • The 165 °C rating covers ambient plus self-temperature rise - the loss budget still has to close at the hot corner, not at 25 °C.
    • Data sheet 4319.

    Putting It to Work

    Choose 6.8 uH when the ripple target is in the middle of the design window: the DCR stays at 41 mOhm and the saturation limit at 2.96 A leaves the transient room it needs.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

    Mechanical Dimensions

    eaton-dra-automotive-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.