Eaton DRA74-100-R AEC-Q200 Shielded Inductor, 10 uH
Eaton DRA74-100-R AEC-Q200 Shielded Inductor, 10 uH

Eaton DRA74-100-R AEC-Q200 Shielded Inductor, 10 uH

Share
Eaton DRA74-100-R: AEC-Q200 Automotive Shielded Drum Core Inductor, 10 uH, 2.56 A, DCR 43 mOhm.
    • Product Details
    • Download

    Eaton DRA74-100-R AEC-Q200 Shielded Inductor, 10 uH

    DRA74-100-R at a glance: shielded drum core inductor, 10 uH, 2.56 A Irms, 2.97 A Isat, DCR 43 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDRA74-100-R
    Rated inductance10 uH ±20%
    Open circuit inductance (OCL)9.62 uH
    Irms (40 °C rise)2.56 A
    Isat1 (30% rolloff @ +25 °C)2.97 A
    Isat2 (40% rolloff @ +125 °C)2.37 A
    DCR typical @ 20 °C43 mOhm
    DCR maximum @ 20 °C52 mOhm
    K-factor (Bp-p = K x L x dI)88.4
    Package7.6 x 7.6 mm footprint
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.

    Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.

    The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.

    Positioning in the Range

    DRA74 shares the 7.6 mm pad with DRA73 and stands taller, which is how it reaches the higher current ratings in this size. AEC-Q200, 165 °C, shielded.

    • Typical applications: Automotive body control, LED drivers, ADAS modules, HVAC and seat controllers, infotainment.
    • Automotive derating practice usually wants margin on both Irms and Isat at the maximum ambient - do not size to the headline numbers alone.
    • Data sheet 4319.

    Design Notes

    Choose 10 uH when the ripple target is in the middle of the design window: the DCR stays at 43 mOhm and the saturation limit at 2.97 A leaves the transient room it needs.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

    Mechanical Dimensions