| Parameter | Value |
|---|---|
| Orderable part number | DRA74-151-R |
| Rated inductance | 150 uH ±20% |
| Open circuit inductance (OCL) | 151 uH |
| Irms (40 °C rise) | 0.66 A |
| Isat1 (30% rolloff @ +25 °C) | 0.75 A |
| Isat2 (40% rolloff @ +125 °C) | 0.6 A |
| DCR typical @ 20 °C | 648 mOhm |
| DCR maximum @ 20 °C | 780 mOhm |
| K-factor (Bp-p = K x L x dI) | 22.3 |
| Package | 7.6 x 7.6 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.
Thermal margin in a module is not the same as thermal margin on a bench. The ratings assume a mounting condition; the enclosure, the potting and the neighbouring components change it.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRA74 shares the 7.6 mm pad with DRA73 and stands taller, which is how it reaches the higher current ratings in this size. AEC-Q200, 165 °C, shielded.
150 uH sits in the middle of the range, and the trade at that point is explicit: 648 mOhm of DCR against 0.75 A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What does AEC-Q200 cover?
The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd