| Parameter | Value |
|---|---|
| Orderable part number | DRA74-221-R |
| Rated inductance | 220 uH ±20% |
| Open circuit inductance (OCL) | 219 uH |
| Irms (40 °C rise) | 0.54 A |
| Isat1 (30% rolloff @ +25 °C) | 0.63 A |
| Isat2 (40% rolloff @ +125 °C) | 0.5 A |
| DCR typical @ 20 °C | 960 mOhm |
| DCR maximum @ 20 °C | 1150 mOhm |
| K-factor (Bp-p = K x L x dI) | 18.6 |
| Package | 7.6 x 7.6 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.
Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DRA74 shares the 7.6 mm pad with DRA73 and stands taller, which is how it reaches the higher current ratings in this size. AEC-Q200, 165 °C, shielded.
At 220 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 960 mOhm DCR - more turns, thinner wire, more resistance.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
What is the operating temperature?
-40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.