
| Parameter | Value |
|---|---|
| Orderable part number | DRA74-2R2-R |
| Rated inductance | 2.2 uH ±20% |
| Open circuit inductance (OCL) | 2.33 uH |
| Irms (40 °C rise) | 4.82 A |
| Isat1 (30% rolloff @ +25 °C) | 6.13 A |
| Isat2 (40% rolloff @ +125 °C) | 4.91 A |
| DCR typical @ 20 °C | 12 mOhm |
| DCR maximum @ 20 °C | 15 mOhm |
| K-factor (Bp-p = K x L x dI) | 183 |
| Package | 7.6 x 7.6 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
AEC-Q200 is the entry ticket, not the destination. This part is qualified to the automotive standard and rated to 165 °C ambient plus self-heating, in a shielded drum core built to survive shock and vibration rather than a laboratory bench.
Thermal margin in a module is not the same as thermal margin on a bench. The ratings assume a mounting condition; the enclosure, the potting and the neighbouring components change it.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRA74 shares the 7.6 mm pad with DRA73 and stands taller, which is how it reaches the higher current ratings in this size. AEC-Q200, 165 °C, shielded.
Choose 2.2 uH when the ripple target is in the middle of the design window: the DCR stays at 12 mOhm and the saturation limit at 6.13 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Is the part shielded?
Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
What does AEC-Q200 cover?
The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd